2x3 drawing

Performance Data*

PLUNGER DIAMETER DISPLACE. PER REV DISPLACEMENT AT PUMP STROKES PER MINUTE/PINION RPM
50/230 120/552 200/920 300/1380 450/2070
In(mm) Gal/rev (liter/rev) gpm (lpm) PSI (MPa) gpm (lpm) PSI (MPa) gpm (lpm) PSI (MPa) gpm (lpm) PSI (MPa) gpm (lpm) PSI (MPa)
3” (76.2) .92 (3.5) 47 (173) 14,147 (97.6) 110 (417) 14,003 (96.6) 183 (695) 8,402 (57.9) 275 (1042) 5,601 (38.6) 413 (1563) 3,734 (25.8)
3 1/2” (88.9) 1.25 (4.7) 62 (237) 10,394 (71.7) 150 (568) 10,288 (71.0) 250 (947) 6,173 (42.3) 375 (1418) 4,115 (28.4) 562 (2128) 2,744 (18.9)
4” (101.6) 1.63 (6.2) 82 (308) 7,958 (54.9) 197 (742) 7,877 (54.3) 327 (1235) 4,726 (32.6) 490 (1853) 3,151 (21.7) 735 (2780) 2,100 (14.5)
4 1/2” (114.3) 2.07 (7.8) 103 (392) 6,288 (43.4) 248 (938) 6,224 (42.9) 413 (1563) 3,734 (25.8) 620 (2345) 2,489 (17.2) 929 (3518) 1,660 (11.4)
INPUT POWER : BHP(Kw) 421(314) 1000(746) 1000(746) 1000(746) 1000(746)

*Based on 90%ME and 100% VE – Intermittent Service Only