Performance Data*
| PLUNGER DIAMETER |
DISPLACE. PER REV |
DISPLACEMENT AT PUMP STROKES PER MINUTE/PINION RPM |
| 50/230 |
120/552 |
200/920 |
300/1380 |
450/2070 |
| In(mm) |
Gal/rev (liter/rev) |
gpm (lpm) |
PSI (MPa) |
gpm (lpm) |
PSI (MPa) |
gpm (lpm) |
PSI (MPa) |
gpm (lpm) |
PSI (MPa) |
gpm (lpm) |
PSI (MPa) |
| 3” (76.2) |
.92 (3.5) |
47 (173) |
14,147 (97.6) |
110 (417) |
14,003 (96.6) |
183 (695) |
8,402 (57.9) |
275 (1042) |
5,601 (38.6) |
413 (1563) |
3,734 (25.8) |
| 3 1/2” (88.9) |
1.25 (4.7) |
62 (237) |
10,394 (71.7) |
150 (568) |
10,288 (71.0) |
250 (947) |
6,173 (42.3) |
375 (1418) |
4,115 (28.4) |
562 (2128) |
2,744 (18.9) |
| 4” (101.6) |
1.63 (6.2) |
82 (308) |
7,958 (54.9) |
197 (742) |
7,877 (54.3) |
327 (1235) |
4,726 (32.6) |
490 (1853) |
3,151 (21.7) |
735 (2780) |
2,100 (14.5) |
| 4 1/2” (114.3) |
2.07 (7.8) |
103 (392) |
6,288 (43.4) |
248 (938) |
6,224 (42.9) |
413 (1563) |
3,734 (25.8) |
620 (2345) |
2,489 (17.2) |
929 (3518) |
1,660 (11.4) |
| INPUT POWER : BHP(Kw) |
421(314) |
1000(746) |
1000(746) |
1000(746) |
1000(746) |
*Based on 90%ME and 100% VE – Intermittent
Service Only
|